Leaderboard

BCI speed records in bits per second

Bits per second (BPS) measures how much information a person with a brain-computer interface (BCI) sends by moving and clicking a cursor on a grid of targets. The record stayed near 4 BPS for seven years, and Neuralink participants have pushed it to 11.32 since 2024. Each row below names the person, the device, the task, and the source.

11.32 BPS

Current record, set by Neuralink participant P15 on Webgrid and reported on October 1, 2026.

4.36 BPS

Best pre-Neuralink grid result, by BrainGate participant T5 in a study published in February 2017.

About 10 BPS

Score of the median Neuralink participant on Webgrid, according to Neuralink in October 2026.

How the record was set: Neuralink's 11.32 BPS record and the 50,000 hours of data behind it.

The record over time

The chart plots only grid-selection results, because those tasks measure the same thing. Results from other tasks are in the leaderboard and marked as not directly comparable.

Cursor speed record, bits per second

Each point is a new best score. Hover over a point for details.

BCI cursor speed record over time, in bits per secondStep chart. BrainGate grid task: 0.93 bits per second in 2015, 4.36 in February 2017. Neuralink Webgrid: 4.6 in early 2024, 8.0 in May 2024, 9.51 in July 2024, 10.39 by November 2025, and 11.32 on October 1, 2026.0369122015201720192021202320252027T6, BrainGate, 2015: 0.93 bpsT5, BrainGate and Stanford, Feb 2017: 4.36 bpsNoland Arbaugh, Neuralink, early 2024: 4.6 bpsNoland Arbaugh, May 2024: 8.0 bpsNoland Arbaugh, Jul 2024: 9.51 bpsParticipant 8, by Nov 2025: 10.39 bpsP15, Oct 1, 2026: 11.32 bps4.364.68.010.3911.32Bits per second
Show the chart data as a table
DateWhoBPS
Nov 2015T6, BrainGate0.93
Feb 2017T5, BrainGate and Stanford4.36
Early 2024Noland Arbaugh, Neuralink4.6
May 2024Noland Arbaugh, Neuralink8.0
Jul 2024Noland Arbaugh, Neuralink9.51
By Nov 2025Participant 8, Neuralink10.39
Oct 2026P15, Neuralink11.32

Leaderboard

Each person's best published result, ranked by BPS. The last column says whether the task can be compared with Neuralink's Webgrid test.

RankWhoDeviceBPSTaskDateSourceCompared with Webgrid
1P15NeuralinkN1 implant11.32WebgridOct 1, 2026NeuralinkSame task
2Participant 8NeuralinkN1 implant10.39Webgrid, 40 by 40 gridBy Nov 2025Neuralink Webgrid pageSame task
3Noland ArbaughNeuralink, patient 1N1 implant9.51Webgrid, 45 by 45 gridJul 2024Neuralink Webgrid pageSame task
4Three patientsStairMed, ShanghaiUltra-flexible electrode implant6.3Cursor control, task not published (reported as 380 bits per minute)Jul 30, 2026Global TimesNot comparable
5T5BrainGate and StanfordTwo 96-channel Utah arrays4.36Grid selection, best block (4.16 average on a 9 by 9 grid)Feb 2017Pandarinath et al., eLifeSimilar task
6Epilepsy patient, age 19NeuroXess, Shanghai256-channel flexible implant4.07Cursor control with an adapted interfaceApr 2025China News ServiceNot comparable
7Participant with ALSUC Davis and BrainGateUtah arrays in the speech motor cortex2.90Cursor target selection and clickNov 2024bioRxiv preprintNot comparable
8T6BrainGateUtah array0.93Grid selectionNov 2015Pandarinath et al., eLife, table 1Similar task

Noland Arbaugh also scored 4.6 BPS in his first research session in early 2024 and 8.0 BPS by May 2024, both reported by Neuralink. Neuralink says three participants beat 10.39 BPS with its new decoders in 2026, and it has published only P15's score. Neuralink has not named P15, and its Webgrid page credits 10.39 to "our eighth clinical trial participant".

Why the numbers are hard to compare

The grid sets the ceiling

Webgrid multiplies the bits in each choice by the net rate of correct selections, which is correct clicks minus wrong ones. A bigger grid packs more bits into each click, and Neuralink's records used 40 by 40 and 45 by 45 grids, far finer than the 6 by 6 and 9 by 9 grids of the 2017 BrainGate study.

Best run or average

Some studies report a session average and others report the best single run. T5 averaged 4.16 BPS on the 9 by 9 grid and peaked at 4.36, while Neuralink lists each participant's best Webgrid score.

Tasks nobody described

The StairMed and NeuroXess figures come from news reports that do not describe the grid or the scoring, so they appear in the leaderboard without a place on the chart.

Records measured in other units

Speech and handwriting BCIs report words or characters per minute, which do not convert to grid BPS.

  • Speech, 62 words per minute: a Stanford participant with ALS, published in 2023. Willett et al., Nature
  • Speech, 97.5% accuracy at about 32 words per minute: a UC Davis participant with ALS over 8.4 months, published in 2024. Card et al., NEJM
  • Handwriting, 90 characters per minute: a Stanford participant with a spinal cord injury who imagined writing letters, published in 2021. Willett et al., Nature

Sources and method

Neuralink's figures come from its own update posts and its Webgrid page, read through Internet Archive snapshots where the page has since changed. Academic figures come from the published papers. Company figures have not appeared in a peer-reviewed journal. Anyone can try the same test with a mouse on Neuralink's Webgrid.

Neura Pod is independent and has no affiliation with Neuralink. Neuralink devices are investigational and not approved by the FDA.